Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.395
Filtrar
2.
Echocardiography ; 41(3): e15785, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38527004

RESUMEN

BACKGROUND: Trans-catheter mitral valve replacement (TMVR) procedures had emerged as an alternative solution for patients who are at high risk for mitral valve surgery. Although cardiac computed tomography (CT) remains the standard method for procedural planning, there is no full agreement on the best systolic phase for quantitation of the neoLVOT. Furthermore, a new three-dimensional trans-esophageal echocardiography (3DTEE) based software was developed to serve as filter and or an alternative for patients who cannot have CT due to any contraindication. AIM: To determine the systolic phase of the cardiac cycle that shows the narrowest NeoLVOT area in order to standardize the way of using these software and then to validate the 3DTEE-based software against the CT-based one as a gold standard, in mitral valve annulus (MA) and NeoLVOT assessment. METHODS: A single center, observational, retrospective study. Initially, a sample of 20 patients (age 62 ± 4 years, 70% men) had CT-based analysis at mid-diastole (80%), early-systole (10%), mid-systole (20%), late-systole (30%-40%), in order to detect the best systolic phase at which the neoLVOT area is the narrowest after TMVR. Then, the end systolic phase was standardized for the analysis of 49 patients (age 57 ± 6 years, 60% men), using both the commercially available CT-based software and the newly available 3DTEE-based software (3mensio Structural Heart, Pie Medical Imaging, The Netherlands). The 3DTEE derived parameters were compared with the gold standard CT-based measurements. RESULTS: The neoLVOT area was significantly narrower at end-systole (224 ± 62 mm2), compared to early-systole (299 ± 70 mm2) and mid-systole (261 ± 75 mm2), (p = .005). Excellent correlation was found between 3DTEE and CT measurements for MA AP diameter (r = .96), IC diameter (r = .92), MA area (r = .96), MA perimeter (r = .94) and NeoLVOT area (r = .96), (all p-values < .0001). Virtual valve sizing was based on annulus measurement and was identical between CT and 3DTEE. Interobserver and intraobserver agreements were excellent for all the measurements with ICCs > .80. CONCLUSIONS: End-systole is the phase that shows the narrowest neoLVOT and hence should be the standard phase used during the analysis. The 3DTEE based analysis using this new software is reliable compared to the CT-based analysis and can be serve as an alternative analysis tool in patients who cannot have CT for any clinical contraindication or as a screening test and/or filter for all patients before proceeding to a detailed CT scan.


Asunto(s)
Ecocardiografía Tridimensional , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Catéteres , Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Estándares de Referencia , Reproducibilidad de los Resultados , Estudios Retrospectivos
3.
Echocardiography ; 41(3): e15798, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38516863

RESUMEN

Editing of 3D raw images acquired during transesophageal echocardiography could be similar to the post processing of raw images with digital software used in photography. 3D image editing in echocardiography is often underestimated in clinical practice, and people are satisfied with the first 3D image they are able to obtain during transesophageal examination. In fact, it is often believed to represent solely an aesthetic addition that does not change the information already obtained with 2D and baseline 3D. In reality, it represents a crucial moment to better understand the mechanisms of mitral pathology, avoiding artifacts and misjudgments. The importance of acquiring raw 3D images of the valve having all the necessary information (ring, the leaflet in toto, the right frame rate) allows us then to edit them making them more beautiful and clearer from the point of view of the information received. Nevertheless, by exclusively acquiring a raw 3D with all the necessary information, we can quickly finish the transesophageal examination, reducing its duration and discomfort for the patient, as well as the inherent risk of complications related to the procedure per se.


Asunto(s)
Ecocardiografía Tridimensional , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Ecocardiografía Tridimensional/métodos , Ecocardiografía/métodos , Ecocardiografía Transesofágica/métodos , Fotograbar
4.
Echocardiography ; 41(3): e15799, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38516862

RESUMEN

Atherosclerosis is the most common cause of heart disease and stroke. Plaque thickness ≥4 mm in the ascending aorta or aortic arch is strongly correlated with cerebral embolic events and ischemic stroke. However, despite imaging workup, the cause of embolic stroke remains unidentified in many patients. Transesophageal echocardiography (TEE) is the preferred echocardiographic method for the evaluation of cardiac source of emboli. 2D TEE imaging evaluates aortic root and aortic arch in a single plane or two planes with biplane imaging. However, 2D TEE often fails to detect mobile or complex components in the ascending aorta and aortic arch plaques. The routine availability of 3D TEE in current ultrasound systems may significantly improve the assessment of aortic plaques as a potential embolic source. In this case series, we present four consecutive patients with stroke who underwent TEE by a single cardiologist for possible cardioembolic source. Some of these patients may have been labelled as "cryptogenic stroke" or "embolic stroke of undetermined source" (ESUS) due to the presence of insignificant or nonmobile ascending aortic or aortic arch plaques on 2D TEE imaging. In our four consecutive patients with ESUS who underwent TEE by a single operator, 3D TEE showed complex aortic arch plaques with ulceration with mobile components and established these plaques as the likely source of embolic stroke.


Asunto(s)
Enfermedades de la Aorta , Aterosclerosis , Accidente Cerebrovascular Embólico , Embolia , Placa Aterosclerótica , Accidente Cerebrovascular , Humanos , Placa Aterosclerótica/complicaciones , Placa Aterosclerótica/diagnóstico por imagen , Ecocardiografía Transesofágica/métodos , Accidente Cerebrovascular Embólico/complicaciones , Aterosclerosis/complicaciones , Aterosclerosis/diagnóstico por imagen , Accidente Cerebrovascular/complicaciones , Accidente Cerebrovascular/diagnóstico por imagen , Aorta Torácica/diagnóstico por imagen , Embolia/complicaciones , Enfermedades de la Aorta/complicaciones , Enfermedades de la Aorta/diagnóstico por imagen
5.
Heart Vessels ; 39(5): 454-463, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38321356

RESUMEN

Cardioembolic stroke is a serious disease with poor prognosis, whose main embolic source is the left atrial appendage (LAA). Left atrial (LA) strain evaluated by the two-dimensional (2D) speckle tracking technique has been proposed. However, the commonly used peak LA strain reflects only LA reservoir function. The LA strain also includes indicators of the other LA functions, such as booster pump function, which reflects active contraction of the LA. This study aimed to investigate whether a newly developed parameter, the left atrial strain time integral (LASTI), can evaluate LAA dysfunction more accurately in patients with acute stroke. We measured LA strain using a 2D speckle tracking method in 168 patients with acute stroke and 20 age-matched control subjects. LASTI was calculated as the area under the LA strain curve in one cardiac cycle. LAA dysfunction was defined as LAA thrombus and/or severe spontaneous echo contrast by transesophageal echocardiography. LASTI was significantly lower in patients with LAA dysfunction than those without. LASTI was a better correlation with LAA blood flow velocity measured by transesophageal echocardiography than peak LA strain. Multivariate logistic regression analysis showed that LASTI was an independent predictor of LAA dysfunction after adjustment for conventional risk factors. LASTI can be a feasible parameter for predicting LAA dysfunction in patients with acute stroke.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Humanos , Apéndice Atrial/diagnóstico por imagen , Accidente Cerebrovascular Isquémico/complicaciones , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Atrios Cardíacos , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/etiología , Ecocardiografía Transesofágica/métodos
6.
J Cardiothorac Vasc Anesth ; 38(5): 1103-1111, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38365466

RESUMEN

OBJECTIVES: To identify trends in the reporting of intraoperative transesophageal echocardiographic (TEE) data in the Society of Thoracic Surgeons (STS) Adult Cardiac Surgery Database (ACSD) and the Adult Cardiac Anesthesiology (ACA) module by period, practice type, and geographic distribution, and to elucidate ongoing areas for practice improvement. DESIGN: A retrospective study. SETTING: STS ACSD. PARTICIPANTS: Procedures reported in the STS ACSD between July 2017 and December 2021 in participating programs in the United States. INTERVENTIONS: None MEASUREMENTS AND MAIN RESULTS: Intraoperative TEE is reported for 73% of all procedures in ACSD. Although the intraoperative TEE data reporting rate increased from 2017 to 2021 for isolated coronary artery bypass graft surgery, it remained low at 62.2%. The reporting of relevant echocardiographic variables across a wide range of procedures has steadily increased over the study period but also remained low. The reporting in the ACA module is high for most variables and across all anesthesia care models; however, the overall contribution of the ACA module to the ACSD remains low. CONCLUSIONS: This progress report suggests a continued need to raise awareness regarding current practices of reporting intraoperative TEE in the ACSD and the ACA, and highlights opportunities for improving reporting and data abstraction.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Cirugía Torácica , Adulto , Humanos , Estados Unidos/epidemiología , Estudios Retrospectivos , Procedimientos Quirúrgicos Cardíacos/métodos , Puente de Arteria Coronaria , Ecocardiografía Transesofágica/métodos
7.
Ultrasound Med Biol ; 50(5): 661-670, 2024 05.
Artículo en Inglés | MEDLINE | ID: mdl-38341361

RESUMEN

OBJECTIVE: Valvular heart diseases (VHDs) pose a significant public health burden, and deciding the best treatment strategy necessitates accurate assessment of heart valve function. Transthoracic echocardiography (TTE) is the key modality to evaluate VHDs, but the lack of standardized quantitative measurements leads to subjective and time-consuming assessments. We aimed to use deep learning to automate the extraction of mitral valve (MV) leaflets and annular hinge points from echocardiograms of the MV, improving standardization and reducing workload in quantitative assessment of MV disease. METHODS: We annotated the MV leaflets and annulus points in 2931 images from 127 patients. We propose an approach for segmenting the annotated features using Attention UNet with deep supervision and weight scheduling of the attention coefficients to enforce saliency surrounding the MV. The derived segmentation masks were used to extract quantitative biomarkers for specific MV leaflet scallops throughout the heart cycle. RESULTS: Evaluation performance was summarized using a Dice score of 0.63 ± 0.14, annulus error of 3.64 ± 2.53 and leaflet angle error of 8.7 ± 8.3°. Leveraging Attention UNet with deep supervision robustness of clinically relevant metrics was improved compared with UNet, reducing standard deviations by 2.7° (angle error) and 0.73 mm (annulus error). We correctly identified cases of MV prolapse, cases of stenosis and healthy references from a clinical material using the derived biomarkers. CONCLUSION: Robust deep learning segmentation and tracking of MV morphology and motion is possible by leveraging attention gates and deep supervision, and holds promise for enhancing VHD diagnosis and treatment monitoring.


Asunto(s)
Aprendizaje Profundo , Ecocardiografía Tridimensional , Enfermedades de las Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Ecocardiografía Tridimensional/métodos , Ecocardiografía/métodos , Biomarcadores , Ecocardiografía Transesofágica/métodos
8.
BMC Cardiovasc Disord ; 24(1): 130, 2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38424513

RESUMEN

INTRODUCTION: We described a rare case of an adolescent girl with paroxysmal atrial fibrillation originating from the right atrial appendage diverticulum and successfully converted to sinus rhythm after surgical intervention. METHODS: A 19-year-old girl was referred to the hospital for a catheter ablation of paroxysmal atrial fibrillation. conventional radiofrequency ablation using 3-D mapping were ineffective. Activation mapping showed the root of the free wall atrial appendage was first excited and catheter modeling (3D Carto map) showed a sac-like structure. RESULTS: We did selective angiography and further Computed tomography angiography (CTA) and Transesophageal echocardiography (TEE) which showed diverticulum originating from the right atrial appendage. Hence the patient was referred to cardiac surgery and had no recurrent atrial fibrillation at three months postoperative follow up. CONCLUSIONS: Right atrial appendage diverticulum was an extremely rare malformation that can coexist with atrial tachyarrhythmia. Surgical ligation or excision of the abnormal structure with local ablation can achieve excellent results.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Femenino , Humanos , Adulto Joven , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/diagnóstico por imagen , Ablación por Catéter/métodos , Ecocardiografía Transesofágica/métodos , Atrios Cardíacos , Taquicardia , Resultado del Tratamiento
9.
Anaesth Crit Care Pain Med ; 43(2): 101346, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38278357

RESUMEN

BACKGROUND: Transesophageal echocardiogram probe insertion in intubated critically ill patients can be difficult, leading to complications, such as gastric bleeding or lesions in the oropharyngeal mucosa. We hypothesised that the use of a videolaryngoscope would facilitate the first attempt at insertion of the transesophageal echocardiogram probe and would decrease the incidence of complications compared to the conventional insertion technique. METHODS: In this clinical trial, patients were randomly assigned the insertion of a transesophageal echocardiogram probe using a videolaryngoscope or conventional technique. The primary outcome was the successful transesophageal echocardiogram probe insertion on the first attempt. The secondary outcomes included total success rate, number of insertion attempts, and incidence of pharyngeal complications. RESULTS: A total of 100 intubated critically ill patients were enrolled. The success rate of transesophageal echocardiogram probe insertion on the first attempt was higher in the videolaryngoscope group than in the conventional group (90% vs. 58%; absolute difference, 32%; 95% CI 16%-48%; p < 0.001). The overall success rate was higher in the videolaryngoscope group than in the conventional group (100% vs. 72%; absolute difference, 28%; 95% CI 16%-40%; p < 0.001). The incidence of pharyngeal mucosal injury was smaller in the videolaryngoscope group than in the conventional group (14% vs. 52%; absolute difference, 38%; 95% CI 21%-55%; p < 0.001). CONCLUSIONS: Our study showed that in intubated critically ill patients required transesophageal echocardiogram, the use of videolaryngoscope resulted in higher successful insertion on the first attempt with lower rate of complications when compared with the conventional insertion technique. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04980976.


Asunto(s)
Laringoscopios , Laringoscopía , Humanos , Laringoscopía/efectos adversos , Laringoscopía/métodos , Ecocardiografía Transesofágica/efectos adversos , Ecocardiografía Transesofágica/métodos , Enfermedad Crítica/terapia , Intubación Intratraqueal/efectos adversos , Intubación Intratraqueal/métodos , Unidades de Cuidados Intensivos
10.
Sci Rep ; 14(1): 11, 2024 01 02.
Artículo en Inglés | MEDLINE | ID: mdl-38167849

RESUMEN

Transesophageal echocardiography (TEE) imaging is a vital tool used in the evaluation of complex cardiac pathology and the management of cardiac surgery patients. A key limitation to the application of deep learning strategies to intraoperative and intraprocedural TEE data is the complexity and unstructured nature of these images. In the present study, we developed a deep learning-based, multi-category TEE view classification model that can be used to add structure to intraoperative and intraprocedural TEE imaging data. More specifically, we trained a convolutional neural network (CNN) to predict standardized TEE views using labeled intraoperative and intraprocedural TEE videos from Cedars-Sinai Medical Center (CSMC). We externally validated our model on intraoperative TEE videos from Stanford University Medical Center (SUMC). Accuracy of our model was high across all labeled views. The highest performance was achieved for the Trans-Gastric Left Ventricular Short Axis View (area under the receiver operating curve [AUC] = 0.971 at CSMC, 0.957 at SUMC), the Mid-Esophageal Long Axis View (AUC = 0.954 at CSMC, 0.905 at SUMC), the Mid-Esophageal Aortic Valve Short Axis View (AUC = 0.946 at CSMC, 0.898 at SUMC), and the Mid-Esophageal 4-Chamber View (AUC = 0.939 at CSMC, 0.902 at SUMC). Ultimately, we demonstrate that our deep learning model can accurately classify standardized TEE views, which will facilitate further downstream deep learning analyses for intraoperative and intraprocedural TEE imaging.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Aprendizaje Profundo , Humanos , Ecocardiografía Transesofágica/métodos , Ecocardiografía/métodos , Válvula Aórtica
11.
J Cardiovasc Electrophysiol ; 35(3): 389-398, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38192059

RESUMEN

INTRODUCTION: This study was performed to explore the diagnostic value of cardiac computed tomography angiography (CCTA) for endothelial insufficiency (EIS) of a left atrial appendage (LAA) disc-like occluder. METHODS: Fifty-nine patients with nonvalvular atrial fibrillation who underwent placement of an LAA disc-like occluder (LAmbre; Lifetech Scientific) in our hospital were retrospectively analyzed. Patients who were found to have contrast agent entering the LAA at the 3-month postoperative CCTA examination underwent Hounsfield unit (HU) measurement of the LAA and construction of a three-dimensional (3D) model of the device for preliminary discernment between peri-device leakage (PDL) and EIS. These patients were then further examined by transesophageal echocardiography (TEE) to check for concordance with the computed tomography (CT) findings. According to the CT and TEE results, all patients were divided into the PDL group, total endothelialization group, and EIS group. The endothelial conditions and other implantation-related results were also tracked at the 6-month follow-up. RESULTS: All 59 patients underwent successful implantation of the LAmbre LAA closure device with no severe adverse events during the procedure. Thirty-five patients were found to have contrast agent entering the LAA at the 3-month postoperative CCTA follow-up. Based on the CT HU measurement and the 3D construction analysis results, these 35 patients were divided into the PDL group (19 patients) and the EIS group (16 patients). In the PDL group, the contrast agent infiltrated from the shoulder along the periphery of the occluder on two-dimensional (2D) CT images, and the 3D model showed a gap between the LAA and the device cover. However, the CCTA images of the other 16 patients in the EIS group showed that the contrast agent in the occluder on the 2D CTA images and 3D construction model confirmed the absence of a gap between the LAA and the device cover. TEE confirmed all of the CT results. The 6-month follow-up results showed that 14 of 19 patients in the EIS group achieved total endothelialization, whereas this number in the PDL group was only five of 19 patients. CONCLUSION: CCTA can replace TEE for examination of the endothelialization status, and patients with EIS have a higher chance of endothelialization than patients with PDL.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Humanos , Angiografía por Tomografía Computarizada/métodos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Estudios Retrospectivos , Medios de Contraste , Tomografía Computarizada por Rayos X , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Ecocardiografía Transesofágica/métodos , Cateterismo Cardíaco/efectos adversos , Resultado del Tratamiento
12.
Ann Noninvasive Electrocardiol ; 29(1): e13104, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38288512

RESUMEN

OBJECTIVE: This study aimed to investigate the structure of the mitral valve in patients undergoing mitral valvuloplasty (MVP) using real-time three-dimensional transesophageal echocardiography (RT-3D-TEE). The main objective was to study the relationship between intraoperative annuloplasty ring size and mitral valve structure dimensions, with a focus on exploring the application value of RT-3D-TEE in MVP. METHODS: A total of 28 patients with degenerative mitral regurgitation (DMR), who underwent MVP between February and September 2022, as well as 12 normal control cases, were enrolled in this study. The MV annulus and leaflets were quantitatively analyzed using MVN software. RESULTS: The DMR group exhibited significantly greater dimensions in various parameters of the mitral valve, including the anterolateral-to-posteromedial diameter (DAlPm ), anterior-to-posterior diameter (DAP ), annulus height (HA ), three-dimensional annulus circumference (CA3D ), two-dimensional annulus area (AA2D ), anterior leaflet area (Aant ), posterior leaflet area (Apost ), anterior leaflet length (Lant ), posterior leaflet length (Lpost ), and tenting volume (Vtent ) compared to the control group. CONCLUSION: Real-time three-dimensional transesophageal echocardiography provides valuable insights into the morphological structure of the mitral valve and lesion location. It can aid in surgical decision-making, validate the success of MVP, and potentially reduce mortality and complications associated with mitral valve repair procedures.


Asunto(s)
Valvuloplastia con Balón , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Insuficiencia de la Válvula Mitral , Humanos , Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/métodos , Electrocardiografía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía
13.
Can J Anaesth ; 71(3): 422-430, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38286981

RESUMEN

PURPOSE: Obtaining an objective, reproducible, and accurate assessment of volume status is one of the more difficult tasks in the perioperative arena. Since its advent in 2020, the Venous Excess Ultrasound (VExUS) score has gained popularity in the minimally invasive assessment of venous congestion. The VExUS exam has been well described as an additional series of images (hepatic vein, portal vein, and intrarenal vein) obtained with a phased-array probe during a transthoracic echocardiogram. Nevertheless, there are no descriptions of comprehensive VExUS exams performed using transesophageal echocardiography (TEE)-a modality that is routinely employed in patients undergoing cardiac surgery. CLINICAL FEATURES: We describe techniques to acquire and interpret a comprehensive TEE-supported VexUS exam, which may be used to optimize the perioperative care of cardiac surgical patients. CONCLUSION: Given the risks of fluid overload in critically ill cardiac surgery patients, TEE-supported VExUS examination may be a way to reduce morbidity in this population.


RéSUMé: OBJECTIF: L'obtention d'une évaluation objective, reproductible et précise du statut volémique est l'une des tâches les plus difficiles dans l'arène périopératoire. Depuis son introduction en 2020, le score VExUS (pour Venous Excess Ultrasound, soit échographie de l'excès veineux) a gagné en popularité dans l'évaluation minimalement invasive de la congestion veineuse. L'examen échographique VExUS a été bien décrit en tant que série supplémentaire d'images (veine hépatique, veine porte et veine intrarénale) obtenues à l'aide d'une sonde type « phased-array ¼ lors d'un échocardiogramme transthoracique. Néanmoins, il n'existe aucune description d'examens VExUS complets réalisés à l'aide d'une sonde d'ETO (échocardiographie transœsophagienne), une modalité couramment utilisée chez les patient·es bénéficiant d'une chirurgie cardiaque. CARACTéRISTIQUES CLINIQUES: Nous décrivons des techniques permettant d'acquérir et d'interpréter un examen VexUS complet par ETO, qui peut être utilisé pour optimiser les soins périopératoires de la patientèle en chirurgie cardiaque. CONCLUSION: Compte tenu des risques de surcharge hydrique chez la patientèle gravement malade en chirurgie cardiaque, l'examen VExUS basé sur l'ETO peut être un moyen de réduire la morbidité dans cette population.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Ecocardiografía Transesofágica , Humanos , Ecocardiografía Transesofágica/métodos , Corazón , Atención Perioperativa/métodos , Venas
14.
BMC Cardiovasc Disord ; 24(1): 51, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-38221637

RESUMEN

Mitral valve aneurysm (MVA) is characterized by a saccular outpouching of the mitral leaflet, and it represents a rare condition typically associated with aortic valve endocarditis. Three-Dimensional Transesophageal Echocardiography (3D-TEE) serves as an effective tool for detecting the presence of MVA and its potential complications. In this report, we present a case involving a young man with striking images of bicuspid aortic valve endocarditis complicated by an aortic root abscess and multiple perforated mitral valve aneurysms, diagnosed using 3D TEE. This case suggests the uncommon coexistence of Marfan like morphotype, bicuspid aortic valve, and infective endocarditis as a triple mechanism in the occurrence of MVA. It underscores the significance of early and accurate imaging diagnosis for facilitating prompt surgical intervention.


Asunto(s)
Enfermedad de la Válvula Aórtica Bicúspide , Ecocardiografía Tridimensional , Endocarditis Bacteriana , Endocarditis , Aneurisma Cardíaco , Síndrome de Marfan , Humanos , Masculino , Absceso/diagnóstico por imagen , Absceso/etiología , Aorta Torácica , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/complicaciones , Ecocardiografía Transesofágica/métodos , Endocarditis/complicaciones , Endocarditis/diagnóstico por imagen , Endocarditis Bacteriana/complicaciones , Endocarditis Bacteriana/diagnóstico por imagen , Endocarditis Bacteriana/cirugía , Aneurisma Cardíaco/etiología , Aneurisma Cardíaco/complicaciones , Síndrome de Marfan/complicaciones , Síndrome de Marfan/diagnóstico , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía
15.
Am J Cardiol ; 211: 287-290, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-37952755

RESUMEN

We aim to evaluate the reliability and consistency of measuring the aortic valve area (AVA) using 3-dimensional (3D) transesophageal echocardiography and compare it with invasive and noninvasive methods using a continuity equation (CE). Measurements were taken from 119 patients with different severity of aortic stenosis and with normal aortic valve who underwent elective transesophageal echocardiography encompassing the whole spectrum of aortic opening. Three methods were compared to determine AVA. First, the effective AVA was calculated with the standard CE, where the left ventricular outflow tract area was calculated from its 2-dimensional diameter (AVA-CEstd). Second, a modified CE method (AVA-CEmod) was used, in which the left ventricular outflow tract area was measured using 3D-multiplane reconstruction. Third, the geometric AVA was directly measured using 3D-multiplane reconstruction planimetry (AVA-3D). Interobserver and intraobserver variability were analyzed using intraclass correlation coefficients (ICCs). The values were measured by two blinded readers for interobserver variability and by one observer on the same dataset. AVA-3D was significantly larger than AVA-CEmod and AVA-CEstd (1.87 ± 1.00 cm2 vs 1.81 ± 0.92 cm2 p = 0.03 and 1.87 ± 1.00 cm2 vs 1.71 ± 0.85 cm2 p <0.001). However, in the subset of patients with AVA-3D <1.5 cm2, there was no significant difference between AVA-3D and AVA-CEmod (1.06 ± 0.24 vs 1.08 ± 0.26 cm2, paired t test: t = 0.77, degree of freedom = 58, p = 0.44). The ICC between the measurements of AVA-3D and AVA-CEmod (ICC 0.979), and AVA-3D and AVA- CEstd (ICC 0.940), were excellent. AVA-3D delivers very similar results as compared with more established echocardiographic parameters. The difference between effective and geometric AVA did not appear to be clinically relevant in patients with a higher degree of stenosis.


Asunto(s)
Estenosis de la Válvula Aórtica , Ecocardiografía Tridimensional , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Reproducibilidad de los Resultados , Ecocardiografía Tridimensional/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Ecocardiografía/métodos , Ecocardiografía Transesofágica/métodos
16.
Am J Vet Res ; 85(1)2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38035479

RESUMEN

OBJECTIVE: To describe the acquisition and pitfalls of a 3-view transesophageal echocardiography (TEE) protocol in anesthetized, dorsally recumbent dogs. ANIMALS: 8 beagles, 1 to 2 years old, 7.4 to 11.2 kg. METHODS: Dogs were anesthetized, mechanically ventilated, and placed in dorsal recumbency. A TEE probe was advanced, and 3 views were performed: midesophageal 4-chamber and long axis (ME 4C and ME LAX) and caudal esophageal short axis (CE SAX) at the level of the papillary muscles. Probe insertion depth, flexion, omniplane angle, and image acquisition time were recorded. Two observers assessed 24 video clips each and identified anatomical structures. RESULTS: The ME 4C and ME LAX were obtained at 35 (30 to 40) cm insertion depth, omniplane at 0° and 103° (90 to 116), respectively. Views were obtained in ≤30 seconds once the TEE was in the cervical esophagus. Left-sided structures were identified in all cases, whereas right-sided structures were not always simultaneously obtained in the ME 4C, requiring further probe manipulation. All structures were identified on ME LAX. CE SAX was obtained at 40 (35 to 45) cm, omniplane at 0°, and in 15 (10 to 90) seconds. A true SAX view (circular left ventricle at the level of papillary muscles) could not be obtained in all dogs. CLINICAL RELEVANCE: A 3-view TEE protocol using core views as those described in humans may be applicable to dogs under general anesthesia and in dorsal recumbency. The CE SAX view at the level of the papillary muscles appears more difficult to obtain with consistency than midesophageal views.


Asunto(s)
Anestesia General , Ecocardiografía Transesofágica , Humanos , Animales , Perros , Ecocardiografía Transesofágica/veterinaria , Ecocardiografía Transesofágica/métodos , Anestesia General/veterinaria , Ventrículos Cardíacos
17.
J Cardiothorac Vasc Anesth ; 38(1): 123-132, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37845143

RESUMEN

OBJECTIVES: To compare transesophageal echocardiography-guided 2-dimensional and M-mode tricuspid annular plane systolic excursion (TAPSE) to transthoracic echocardiography (TTE)-guided M-mode TAPSE in terms of accuracy, interobserver, and intra-observer variability. DESIGN: A prospective, observational study. SETTING: Adult and pediatric operating rooms. PARTICIPANTS: Adult and pediatric patients (42 each) undergoing cardiac surgeries. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Modified midesophageal (Mod-ME), deep transgastric, and transgastric TAPSEs were analyzed for reliability and were compared to TTE TAPSE in both adult and pediatric groups. Modified ME TAPSE showed good method agreement with TTE TAPSE (bias = -0.97, p = 0.08 (adult); bias = 0.17, p = 0.71 [pediatric]), and showed a moderate correlation with right ventricular (RV) fractional area change (FAC) (r = 0.41, p = 0.006, [adult]; r = 0.57, p < 0.001, [pediatric]), with acceptable interobserver variability (percentage error =10.56 [adult]; 4.42 [pediatric]) and intraobserver variability (percentage error = 13.1 [adults]; 12.24 [pediatric]). Transgastric TAPSE poorly agreed with TTE TAPSE and had higher interobserver and intraobserver variability. Deep transgastric TAPSE had good method agreement with TTE TAPSE and had acceptable interobserver and intra-observer variability. CONCLUSIONS: Modified ME TAPSE is a reliable and reproducible measure of RV function before pericardiotomy in both adult and pediatric cardiac surgery. Right ventricular FAC values reflected the RV systolic function better than TAPSE after pericardiotomy. Deep transgastric TAPSE is reliable and reproducible but is less accurate than Mod-ME TAPSE.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Disfunción Ventricular Derecha , Adulto , Humanos , Niño , Ecocardiografía Transesofágica/métodos , Estudios Prospectivos , Función Ventricular Derecha , Reproducibilidad de los Resultados , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Ecocardiografía
19.
Rev Esp Anestesiol Reanim (Engl Ed) ; 71(1): 48-53, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37678467

RESUMEN

Video-assisted thoracoscopy (VATS) cardiac surgery requires one-lung ventilation (OLV) and transoesophageal ultrasound (TOE) monitoring. Colour and spectral Doppler make it possible to study the pattern of blood flow in the pulmonary vessels within the atelectatic lung. In this case report we describe how TOE can be used to detect blood flow within the atelectatic lung and to assess pulmonary vascular resistance (PVR) and right ventricular (RV) afterload. FINDINGS: Three anaesthetised, mechanically ventilated adults scheduled for cardiac surgery by VATS were scanned with TOE. After left OLV, the transducer was rotated away from the heart to obtain 2D colour Doppler images of blood flow within the consolidated lung parenchyma. We were able to identify the flow pattern of the intrapulmonary branches of the pulmonary artery. PVR was recorded using pulsed cardiac Doppler at baseline, after induction of general anaesthesia, 20 min after OLV and at the end of OLV, and after performing an alveolar recruitment manoeuvre (ARM) that led to complete resolution of the aforementioned consolidation. CONCLUSIONS: TOE is a semi-invasive imaging tool that can be used to diagnose and study PVR-induced atelectasis and to analyse the resulting pulmonary shunt and its possible effect on PVR.


Asunto(s)
Ventilación Unipulmonar , Atelectasia Pulmonar , Humanos , Ecocardiografía Transesofágica/métodos , Pulmón , Atelectasia Pulmonar/diagnóstico por imagen , Arterias
20.
Echocardiography ; 41(1): e15724, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38064288

RESUMEN

BACKGROUND AND AIM: Our aim was to evaluate the fluoroscopy time (FT), procedure time (PT) safety and efficacy when using intracardiac echocardiography (ICE) in comparison to transesophageal echocardiography (TEE) guidance for transcatheter closure of Ostium Secundum Atrial Septal Defect (OS-ASD). METHOD: Ninety patients (n = 90) diagnosed with OS-ASD underwent transcatheter closure between March 2006 and October 2021. Fifty-seven patients were treated under ICE guidance, while 33 patients were treated under TEE guidance. RESULTS: Mean age was 43 ± 15 years and 42 ± 10 years in the ICE and TEE groups, respectively. The majority of patients had a centrally placed defect. Median FT was 8.40 min versus 11.70 min (p < .001) in the ICE group compared to the TEE group, respectively. Median PT was 43 min versus 94 min (p < .001) in the ICE group compared to the TEE group, respectively. Both ICE and TEE provided high quality images. All interventions were completed successfully, except for one patient in the ICE group who experienced a device migration, the development of atrial tachycardia in one patient and atrial fibrillation in two patients in the ICE group which spontaneously cardioverted. There were no other complications. CONCLUSION: This study on a consistent cohort of patients with OS-ASD undergoing percutaneous closure suggests that use of ICE is safe and efficacious. Compared to TEE, ICE demonstrated significantly shorter FT and PT, decreasing the entire duration of the procedure and x-ray exposure. No relevant differences were observed in terms of success rate and complications.


Asunto(s)
Fibrilación Atrial , Defectos del Tabique Interatrial , Humanos , Adulto , Persona de Mediana Edad , Ecocardiografía Transesofágica/métodos , Cateterismo Cardíaco/métodos , Defectos del Tabique Interatrial/diagnóstico por imagen , Defectos del Tabique Interatrial/cirugía , Fluoroscopía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...